Print Back
These cartridges feature the latest technology in filter media. Layers of melt-blown and spun-bonded polypropylenes combine to produce nominal retentions from 0.1 micron to 30 micron. Polypropylene cartridges feature popular end cap styles which fit most standard and sanitary style housings. Ideal as low cost membrane prefilters, these high efficiency cartridges serve a wide range of applications.
Unit of Measure

Specifications

Type

N/A Standard

Media

N/A Polypropylene (FDA Grade)

End Caps

N/A 2 3/4" Polypropylene

Micron Rating

N/A 1

Length

N/A 5"

O.D.

N/A 2 3/4" OD x 1" ID (2 1/2" OD Available)

Cartridge Style Options

N/A T = SOE 020 (Gelman Style) X = Extended Core L = 226 O-Ring (Closed End) M = 226 O-Ring (Fin End) R = SOE 118 (Internal O-Ring) H = DOE PP (Double Open End) J = 222 O-ring (Closed End) K = 222 O-Ring (Fin End)

Gasket Material Options

N/A S = Silicone (Viton and Teflon Available) E = EPR (Viton and Teflon Available) N = Buna (Viton and Teflon Available)

Support Materials

N/A Polypropylene

Operating Characteristics

N/A Maxiumum delta P=60 psi at maximum recommended temperature of 140 degrees F. Change out recommended at 30 psid.

Features

N/A

Specifications:

MATERIALS OF CONSTRUCTION*:
Filter Media: Polypropylene
Support Materials: Polypropylene
Thermal Bonded End Caps: Polypropylene

NOMINAL MICRON RATINGS:
0.1, 0.2, 0.45, 1.0, 3.0, 10.0, 20.0, 30.0
Ratings derived from independent laboratory tests using latex bead suspensions and particle counter readings.

EFFECTIVE FILTRATION AREA:
4-1/2 square feet per layer per 10 inch length

DIMENSIONS:
2-3/4" or 2-1/2" OD x 1" ID
Nominal 5", 9.75", 10", 19.5", 20", 29.25", 30", 39", 40" lengths

OPERATING CHARACTERISTICS:
Maximum Differential Pressure=60 psi at maximum recommended
temperature of 140°F. Change out recommended at 30 psid.

*The materials used are acceptable for potable and edible liquid contact according to FDA CFR Title 21.